News

The Reasons Why Barrier Gate Doesn't Close

A barrier gate that does not close after a vehicle has passed is a problem customers sometimes encounter. The COMA car parking supplier introduces some methods to check it.

%smart parking system%

  1. The grounding loop is buried incorrectly, or the coil is damaged or broken.

  2. The power supply of the vehicle detector is insufficient (maximum 250 mA), or the sensor sensitivity is not adjusted properly (too high or too low).

  3. The line encounters strong interference, such as when the communication line and the AC power line are laid in the same conduit.

  4. If the line is too long and exceeds the effective communication distance (200 m), the signal will be seriously attenuated.

  5. The ground terminal (signal ground) of the card reader control board and the AC power supply (power ground) are short-circuited, causing communication interference. When disconnected from the factory, they are in an offline working state; when connected to the computer, they must be short-circuited online.

  6. The communication between the computer and the card reader is not working properly, so the controller cannot receive the door-open command.

COMA parking manufacturers have delivered more than 9,000 parking projects around the world. Parking entry ticket machines, exit ticket machines, card dispenser machines, ANPR/LPR barrier gate systems, smart parking management system software, parking flap lock units for outdoor parking, pay-and-display parking meters and toll management systems are our strengths.